Kernel driver max16064¶
Supported chips:
Maxim MAX16064
Prefix: ‘max16064’
Addresses scanned: -
Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX16064.pdf
Author: Guenter Roeck <linux@roeck-us.net>
Description¶
This driver supports hardware monitoring for Maxim MAX16064 Quad Power-Supply Controller with Active-Voltage Output Control and PMBus Interface.
The driver is a client driver to the core PMBus driver. Please see Documentation/hwmon/pmbus.rst for details on PMBus client drivers.
Usage Notes¶
This driver does not auto-detect devices. You will have to instantiate the devices explicitly. Please see Documentation/i2c/instantiating-devices for details.
Platform data support¶
The driver supports standard PMBus driver platform data.
Sysfs entries¶
The following attributes are supported. Limits are read-write; all other attributes are read-only.
in[1-4]_label | “vout[1-4]” |
in[1-4]_input | Measured voltage. From READ_VOUT register. |
in[1-4]_min | Minimum Voltage. From VOUT_UV_WARN_LIMIT register. |
in[1-4]_max | Maximum voltage. From VOUT_OV_WARN_LIMIT register. |
in[1-4]_lcrit | Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register. |
in[1-4]_crit | Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. |
in[1-4]_min_alarm | Voltage low alarm. From VOLTAGE_UV_WARNING status. |
in[1-4]_max_alarm | Voltage high alarm. From VOLTAGE_OV_WARNING status. |
in[1-4]_lcrit_alarm | Voltage critical low alarm. From VOLTAGE_UV_FAULT status. |
in[1-4]_crit_alarm | Voltage critical high alarm. From VOLTAGE_OV_FAULT status. |
in[1-4]_highest | Historical maximum voltage. |
in[1-4]_reset_history | Write any value to reset history. |
temp1_input | Measured temperature. From READ_TEMPERATURE_1 register. |
temp1_max | Maximum temperature. From OT_WARN_LIMIT register. |
temp1_crit | Critical high temperature. From OT_FAULT_LIMIT register. |
temp1_max_alarm | Chip temperature high alarm. Set by comparing READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING status is set. |
temp1_crit_alarm | Chip temperature critical high alarm. Set by comparing READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT status is set. |
temp1_highest | Historical maximum temperature. |
temp1_reset_history | Write any value to reset history. |