Kernel driver ina3221

Supported chips:

  • Texas Instruments INA3221

    Prefix: ‘ina3221’

    Addresses: I2C 0x40 - 0x43

    Datasheet: Publicly available at the Texas Instruments website

Author: Andrew F. Davis <afd@ti.com>

Description

The Texas Instruments INA3221 monitors voltage, current, and power on the high side of up to three D.C. power supplies. The INA3221 monitors both shunt drop and supply voltage, with programmable conversion times and averaging, current and power are calculated host-side from these.

Sysfs entries

in[123]_label Voltage channel labels
in[123]_enable Voltage channel enable controls
in[123]_input Bus voltage(mV) channels
curr[123]_input Current(mA) measurement channels
shunt[123]_resistor Shunt resistance(uOhm) channels
curr[123]_crit Critical alert current(mA) setting, activates the corresponding alarm when the respective current is above this value
curr[123]_crit_alarm Critical alert current limit exceeded
curr[123]_max Warning alert current(mA) setting, activates the corresponding alarm when the respective current average is above this value.
curr[123]_max_alarm Warning alert current limit exceeded
in[456]_input Shunt voltage(uV) for channels 1, 2, and 3 respectively
samples

Number of samples using in the averaging mode.

Supports the list of number of samples:

1, 4, 16, 64, 128, 256, 512, 1024
update_interval

Data conversion time in millisecond, following:

update_interval = C x S x (BC + SC)

  • C: number of enabled channels
  • S: number of samples
  • BC: bus-voltage conversion time in millisecond
  • SC: shunt-voltage conversion time in millisecond

Affects both Bus- and Shunt-voltage conversion time. Note that setting update_interval to 0ms sets both BC and SC to 140 us (minimum conversion time).