6.1. Introduction

LIRC stands for Linux Infrared Remote Control. The LIRC device interface is a bi-directional interface for transporting raw IR and decoded scancodes data between userspace and kernelspace. Fundamentally, it is just a chardev (/dev/lircX, for X = 0, 1, 2, …), with a number of standard struct file_operations defined on it. With respect to transporting raw IR and decoded scancodes to and fro, the essential fops are read, write and ioctl.

It is also possible to attach a BPF program to a LIRC device for decoding raw IR into scancodes.

Example dmesg output upon a driver registering w/LIRC:

$ dmesg |grep lirc_dev
rc rc0: lirc_dev: driver mceusb registered at minor = 0, raw IR receiver, raw IR transmitter

What you should see for a chardev:

$ ls -l /dev/lirc*
crw-rw---- 1 root root 248, 0 Jul 2 22:20 /dev/lirc0

Note that the package v4l-utils contains tools for working with LIRC devices:

  • ir-ctl: can receive raw IR and transmit IR, as well as query LIRC device features.
  • ir-keytable: can load keymaps; allows you to set IR kernel protocols; load BPF IR decoders and test IR decoding. Some BPF IR decoders are also provided.

6.2. LIRC modes

LIRC supports some modes of receiving and sending IR codes, as shown on the following table.

LIRC_MODE_SCANCODE

This mode is for both sending and receiving IR.

For transmitting (aka sending), create a struct lirc_scancode with the desired scancode set in the scancode member, rc_proto set to the IR protocol, and all other members set to 0. Write this struct to the lirc device.

For receiving, you read struct lirc_scancode from the LIRC device. The scancode field is set to the received scancode and the IR protocol is set in rc_proto. If the scancode maps to a valid key code, this is set in the keycode field, else it is set to KEY_RESERVED.

The flags can have LIRC_SCANCODE_FLAG_TOGGLE set if the toggle bit is set in protocols that support it (e.g. rc-5 and rc-6), or LIRC_SCANCODE_FLAG_REPEAT for when a repeat is received for protocols that support it (e.g. nec).

In the Sanyo and NEC protocol, if you hold a button on remote, rather than repeating the entire scancode, the remote sends a shorter message with no scancode, which just means button is held, a “repeat”. When this is received, the LIRC_SCANCODE_FLAG_REPEAT is set and the scancode and keycode is repeated.

With nec, there is no way to distinguish “button hold” from “repeatedly pressing the same button”. The rc-5 and rc-6 protocols have a toggle bit. When a button is released and pressed again, the toggle bit is inverted. If the toggle bit is set, the LIRC_SCANCODE_FLAG_TOGGLE is set.

The timestamp field is filled with the time nanoseconds (in CLOCK_MONOTONIC) when the scancode was decoded.

LIRC_MODE_MODE2

The driver returns a sequence of pulse and space codes to userspace, as a series of u32 values.

This mode is used only for IR receive.

The upper 8 bits determine the packet type, and the lower 24 bits the payload. Use LIRC_VALUE() macro to get the payload, and the macro LIRC_MODE2() will give you the type, which is one of:

LIRC_MODE2_PULSE

Signifies the presence of IR in microseconds.

LIRC_MODE2_SPACE

Signifies absence of IR in microseconds.

LIRC_MODE2_FREQUENCY

If measurement of the carrier frequency was enabled with ioctl LIRC_SET_MEASURE_CARRIER_MODE then this packet gives you the carrier frequency in Hertz.

LIRC_MODE2_TIMEOUT

If timeout reports are enabled with ioctl LIRC_SET_REC_TIMEOUT_REPORTS, when the timeout set with ioctl LIRC_GET_REC_TIMEOUT and LIRC_SET_REC_TIMEOUT expires due to no IR being detected, this packet will be sent, with the number of microseconds with no IR.

LIRC_MODE_PULSE

In pulse mode, a sequence of pulse/space integer values are written to the lirc device using LIRC write().

The values are alternating pulse and space lengths, in microseconds. The first and last entry must be a pulse, so there must be an odd number of entries.

This mode is used only for IR send.

6.3. Data types used by LIRC_MODE_SCANCODE

struct lirc_scancode

decoded scancode with protocol for use with LIRC_MODE_SCANCODE

Definition

struct lirc_scancode {
  __u64 timestamp;
  __u16 flags;
  __u16 rc_proto;
  __u32 keycode;
  __u64 scancode;
};

Members

timestamp
Timestamp in nanoseconds using CLOCK_MONOTONIC when IR was decoded.
flags
should be 0 for transmit. When receiving scancodes, LIRC_SCANCODE_FLAG_TOGGLE or LIRC_SCANCODE_FLAG_REPEAT can be set depending on the protocol
rc_proto
see enum rc_proto
keycode
the translated keycode. Set to 0 for transmit.
scancode
the scancode received or to be sent
enum rc_proto

the Remote Controller protocol

Constants

RC_PROTO_UNKNOWN
Protocol not known
RC_PROTO_OTHER
Protocol known but proprietary
RC_PROTO_RC5
Philips RC5 protocol
RC_PROTO_RC5X_20
Philips RC5x 20 bit protocol
RC_PROTO_RC5_SZ
StreamZap variant of RC5
RC_PROTO_JVC
JVC protocol
RC_PROTO_SONY12
Sony 12 bit protocol
RC_PROTO_SONY15
Sony 15 bit protocol
RC_PROTO_SONY20
Sony 20 bit protocol
RC_PROTO_NEC
NEC protocol
RC_PROTO_NECX
Extended NEC protocol
RC_PROTO_NEC32
NEC 32 bit protocol
RC_PROTO_SANYO
Sanyo protocol
RC_PROTO_MCIR2_KBD
RC6-ish MCE keyboard
RC_PROTO_MCIR2_MSE
RC6-ish MCE mouse
RC_PROTO_RC6_0
Philips RC6-0-16 protocol
RC_PROTO_RC6_6A_20
Philips RC6-6A-20 protocol
RC_PROTO_RC6_6A_24
Philips RC6-6A-24 protocol
RC_PROTO_RC6_6A_32
Philips RC6-6A-32 protocol
RC_PROTO_RC6_MCE
MCE (Philips RC6-6A-32 subtype) protocol
RC_PROTO_SHARP
Sharp protocol
RC_PROTO_XMP
XMP protocol
RC_PROTO_CEC
CEC protocol
RC_PROTO_IMON
iMon Pad protocol
RC_PROTO_RCMM12
RC-MM protocol 12 bits
RC_PROTO_RCMM24
RC-MM protocol 24 bits
RC_PROTO_RCMM32
RC-MM protocol 32 bits
RC_PROTO_XBOX_DVD
Xbox DVD Movie Playback Kit protocol
RC_PROTO_MAX
Maximum value of enum rc_proto

6.4. BPF based IR decoder

The kernel has support for decoding the most common IR protocols, but there are many protocols which are not supported. To support these, it is possible to load an BPF program which does the decoding. This can only be done on LIRC devices which support reading raw IR.

First, using the bpf(2) syscall with the BPF_LOAD_PROG argument, program must be loaded of type BPF_PROG_TYPE_LIRC_MODE2. Once attached to the LIRC device, this program will be called for each pulse, space or timeout event on the LIRC device. The context for the BPF program is a pointer to a unsigned int, which is a LIRC_MODE_MODE2 value. When the program has decoded the scancode, it can be submitted using the BPF functions bpf_rc_keydown() or bpf_rc_repeat(). Mouse or pointer movements can be reported using bpf_rc_pointer_rel().

Once you have the file descriptor for the BPF_PROG_TYPE_LIRC_MODE2 BPF program, it can be attached to the LIRC device using the bpf(2) syscall. The target must be the file descriptor for the LIRC device, and the attach type must be BPF_LIRC_MODE2. No more than 64 BPF programs can be attached to a single LIRC device at a time.